// Projects · Survey & Diagnostic Records

Recent surveys
& investigations.

A selection of recent diagnostic commissions, from car park decks to basement beams. Every job starts with a defect survey, corrosion assessment and a costed recommendation.

Basement Beam, Reinforcement Corrosion Survey
REF · CI-0142
Basement Beam · Survey
Sussex, UK 2025

Basement Beam, Reinforcement Corrosion Survey

// Observation

A structural beam within a residential basement showed localised spalling and rust staining. On close inspection sections of the main tensile reinforcement had lost significant cover, with visible corrosion along the bar.

// Investigation

Element inspected with hammer-tap and cover meter survey. Photographic defect register produced and the extent of delamination mapped. Corrosion mechanism assessed against cover, exposure and construction date to inform the repair strategy.

// Recommendation

Recommendation issued: breakout to 25 mm behind the affected bars, grit-blast to SA 2½, zinc-rich primer to reinforcement, and reinstatement in an EN 1504-3 R4 repair mortar. Costed scope of works provided to the client for approval.

Office Block Column, Diagnostic Investigation
REF · CI-0139
Office Column · Investigation
Kent, UK 2025

Office Block Column, Diagnostic Investigation

// Observation

A load-bearing column within a commercial office block presented with cracking and localised concrete loss. Initial breakout for inspection exposed heavily corroded main bar and stirrups within a narrow section, with cover to reinforcement below specification.

// Investigation

Investigative breakout in a small trial area to expose the reinforcement and assess bar condition. Cover measured and photographed. Corrosion pattern assessed to distinguish between generalised (carbonation) and localised (chloride) mechanisms.

// Recommendation

Findings reported to the client with a recommended repair strategy: temporary support during works, breakout around the affected reinforcement, cleaning and treatment of the bar, and reinstatement in a flowable R4 micro-concrete to restore cover.

Car Park Waffle Slab, Soffit Survey
REF · CI-0137
Car Park · Waffle Slab Survey
London, UK 2025

Car Park Waffle Slab, Soffit Survey

// Observation

Extensive soffit spalling and delamination across the waffle-slab soffit of a car park deck. Multiple ribs affected, with exposed and visibly corroded bottom-steel across a substantial area, driven by chloride ingress from de-icing salts.

// Investigation

Deck soffit surveyed rib-by-rib with hammer-tap, cover meter and photographic capture. Extent of delamination mapped onto a plan and severity graded. Chloride profile assessed to confirm the corrosion mechanism.

// Recommendation

Recommended phased repair programme: breakout per affected rib, grit-blast and prime the reinforcement, reinstate in a fibre-reinforced repair mortar spray-applied and finished to the waffle profile. Anti-carbonation coating and galvanic anodes advised as part of the whole-element strategy.

Office Block Slab Soffit, Defect Survey
REF · CI-0128
Office Slab · Defect Survey
United Kingdom 2025

Office Block Slab Soffit, Defect Survey

// Observation

Slab soffit within an office block showed a series of isolated spalls with visibly corroded reinforcement. Historic water ingress from a floor above had driven long-term corrosion of the bottom mat across several locations.

// Investigation

Soffit surveyed and each affected patch measured, photographed and logged onto a defect register. Extent of delamination mapped. Recommendation prepared for phased remediation to allow occupied use to continue.

// Recommendation

Client received a full defect register with photographs, extent of works and a costed repair specification. Recommended R3 trowel-applied mortar reinstatement with feathered edges to allow a paint-ready finish once complete.

// Your project

Could be next on our books.

Send us a photograph, a location and a short description. We'll come back with a scope of investigation and a view on likely repair strategy.

Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·Diagnose · Break Out · Treat · Rebuild ·
Concrete Insight UK Ltd

Specialist diagnosis and repair of reinforced concrete affected by chemical attack (chlorides, carbonation, sulphates, ASR), reinforcement corrosion and fire damage. Investigation, breakout, treatment and full reinstatement, one accountable team.

// Contact
  • (+44) 0203 733 2108
  • info@concreteinsightuk.co.uk
  • Nationwide, United Kingdom
Request Site Visit
© 2026 Concrete Insight UK Ltd · All rights reserved
PrivacyCookiesTerms